GASCONVERSION
WARNING!
Beforecarryingoutthisoperation,disconnect
theappliancefromgasandelectricity.
Gasconversionshallbeconductedbyafactory
trainedprofessional.
Callthecustomerservicehotlinetoidentifya
factorytrainedprofessionalnearyourhome.
The gas conversion procedure for this range
includes6steps:
1. Pressureregulator
2. Surfaceburn ers
3. Mainovenburner
4. Broilerburner
5. Visualcheckspriortoclosureofovenbottom
panel
6. Adjustmentofminimumsetting
The conversion is not completed if all 6 steps
havenotbeenconcludedproperly.
Beforeperformingthegasconversion,locatethe
packagecontainingthereplacementnozzle
shippedwitheveryrange.IMPORTANT:Each
nozzlehasanumberindicating itsflowdiameter
printedonthebody.Consultthetableonpage20
formatchingnozzlestoburners.
Savethenozzlesremovedfromtherangefor
futureuse.
STEP1:PRESSUREREGULATOR
Thepressureregulatorsuppliedwiththe
applianceisaconvertibletypepressure regulator
forusewithLP/PropaneGasatanominaloutlet
pressureof11”w.c.orNaturalgasatanominal
outletpressureof4”w.c.anditisprearranged
fromthefactorytooperatewithoneofthese
gas/pressureasindicatedinthelabelsaffixed
on
theappliance,packageandInstructionbooklet.
Toconverttheregulatorforusewithother
Naruralgas:
1. Unscrewbyhandtheuppercapofthe
regulator,removethewhiteplastic
attachmentfromthecap,reverseits
directionandscrewitagainfirmlyagainstthe
cap.Thewhiteplasticattachment
hasarrows
indicatingthepositionforLPgas(LP)and
naturalgas(NAT).
2. Screwbyhandthemetalcapintheoriginal
positionontheregulator.